AGP3R2Particle filter P3, bayonet

Particle filter P3, glass fibre

Particle filter of class P3 with glass fibre filter medium in a grey plastic housing. It sits in pairs on the bayonet connections of the half masks AG360 and AG360W or at the sides of the full-face mask AG700.

Marking
P3
Standard
EN 143:2021
Connection
Bayonet
Fits
AG360/W and AG700
PPE category
III, CE 2834
Packaging
72 pairs

Data sheet (PDF)Ask for advice

Warnings

  • Particle filters do not protect against gases and vapours.
  • Filters do not supply oxygen: do not use where the oxygen content may be too low (below 19.5 % by volume according to the instructions for use), in tanks, pits, shafts and confined spaces, or if the substance and its concentration are not known.
  • Use only with the AirGuard Pro masks named in the documents.

The instructions for use of the product are authoritative.

AirGuard Pro Particle filter P3, glass fibre AGP3R2, grey

In a housing instead of a disc

Unlike the flat AGP3R1, the AGP3R2 has its filter medium in a solid housing. Both are P3 filters to EN 143:2021 for the same masks. Which one suits better in daily use is easiest to see with a sample in a wearing trial.

With the half mask AG360 the filter is permitted up to 30 times the workplace exposure limit under DGUV Rule 112-190, with the full-face mask AG700 up to 400 times. How the protection level is calculated is explained under Half mask or full-face mask.

Replacement and storage

Particle filters are replaced when breathing becomes noticeably harder, when they are damaged or when the expiry date is reached. They do not protect against gases and vapours. The instructions for use for AGP3R2 are available on request; their information on the period of use is authoritative.

The filter is packed 6 pairs per box, 72 pairs per carton.

Using correctly

  1. 01

    Open only at the place of use

    Take the filter out of its packaging immediately before use and check the expiry date on the filter.

  2. 02

    Fit in pairs

    Place two identical filters on the bayonet connections of the mask and turn until they sit firmly.

  3. 03

    Check the face seal

    Place the palm of your hand over the exhalation valve and exhale slowly. If air escapes at the edge of the mask, reposition it and tighten the straps. Before every use.

  4. 04

    Replace in good time

    When breathing becomes noticeably harder or the filter is damaged or soiled. Always replace both filters together.

When filters are replaced

Technical data

Technical data AGP3R2
Article numberAGP3R2
TypeParticle filter
Colourgrey
StandardEN 143:2021
MarkingP3
Particle filterP3
ConnectionBayonet connection, two filters
FitsAG360, AG360W and AG700
PPE categoryIII under Regulation (EU) 2016/425
Notified bodyCCQS Certification Services Limited, 2834
EU type examinationCE-PC-240129-058-02-9A of 24 Oct 2024
Packaging72 pairs, 6 pairs per box

Frequently asked questions

What is the difference between AGP3R1 and AGP3R2?

Both are P3 filters to EN 143:2021 with bayonet connection for AG360, AG360W and AG700. AGP3R1 is a flat filter disc, AGP3R2 has a glass fibre filter medium in a plastic housing.

How many filters are in one box?

6 pairs per box, 72 pairs per carton.

Does the AGP3R2 protect against gases?

No. Against gases and vapours you need a gas or combination filter, for example AGABEKK1P3.

The brand family of DS SafetyWear Arbeitsschutzprodukte GmbH