Particle filter P3, glass fibre
Particle filter of class P3 with glass fibre filter medium in a grey plastic housing. It sits in pairs on the bayonet connections of the half masks AG360 and AG360W or at the sides of the full-face mask AG700.
- Marking
- P3
- Standard
- EN 143:2021
- Connection
- Bayonet
- Fits
- AG360/W and AG700
- PPE category
- III, CE 2834
- Packaging
- 72 pairs
Data sheet (PDF)Ask for advice
Warnings
- Particle filters do not protect against gases and vapours.
- Filters do not supply oxygen: do not use where the oxygen content may be too low (below 19.5 % by volume according to the instructions for use), in tanks, pits, shafts and confined spaces, or if the substance and its concentration are not known.
- Use only with the AirGuard Pro masks named in the documents.
The instructions for use of the product are authoritative.

In a housing instead of a disc
Unlike the flat AGP3R1, the AGP3R2 has its filter medium in a solid housing. Both are P3 filters to EN 143:2021 for the same masks. Which one suits better in daily use is easiest to see with a sample in a wearing trial.
With the half mask AG360 the filter is permitted up to 30 times the workplace exposure limit under DGUV Rule 112-190, with the full-face mask AG700 up to 400 times. How the protection level is calculated is explained under Half mask or full-face mask.
Replacement and storage
Particle filters are replaced when breathing becomes noticeably harder, when they are damaged or when the expiry date is reached. They do not protect against gases and vapours. The instructions for use for AGP3R2 are available on request; their information on the period of use is authoritative.
The filter is packed 6 pairs per box, 72 pairs per carton.
Using correctly
- 01
Open only at the place of use
Take the filter out of its packaging immediately before use and check the expiry date on the filter.
- 02
Fit in pairs
Place two identical filters on the bayonet connections of the mask and turn until they sit firmly.
- 03
Check the face seal
Place the palm of your hand over the exhalation valve and exhale slowly. If air escapes at the edge of the mask, reposition it and tighten the straps. Before every use.
- 04
Replace in good time
When breathing becomes noticeably harder or the filter is damaged or soiled. Always replace both filters together.
Technical data
| Article number | AGP3R2 |
|---|---|
| Type | Particle filter |
| Colour | grey |
| Standard | EN 143:2021 |
| Marking | P3 |
| Particle filter | P3 |
| Connection | Bayonet connection, two filters |
| Fits | AG360, AG360W and AG700 |
| PPE category | III under Regulation (EU) 2016/425 |
| Notified body | CCQS Certification Services Limited, 2834 |
| EU type examination | CE-PC-240129-058-02-9A of 24 Oct 2024 |
| Packaging | 72 pairs, 6 pairs per box |
Downloads
Instructions for use on request: Request documents
Frequently asked questions
What is the difference between AGP3R1 and AGP3R2?
Both are P3 filters to EN 143:2021 with bayonet connection for AG360, AG360W and AG700. AGP3R1 is a flat filter disc, AGP3R2 has a glass fibre filter medium in a plastic housing.
How many filters are in one box?
6 pairs per box, 72 pairs per carton.
Does the AGP3R2 protect against gases?
No. Against gases and vapours you need a gas or combination filter, for example AGABEKK1P3.
Goes with it
To the respirator finderParticle filter P3, bayonet
Particle filter P3 R with bayonet connection
AGP3R1
- Class
- P3 R
- Connection
- Bayonet
- Fits
- Half and full-face mask
- 2 colours
Half mask, reusable
Half-mask respirator AG360
AG360, AG360W
- Standard
- EN 140:1998
- Connection
- Bayonet
- Protects up to
- 30× AGW
Full-face mask, reusable
Full-face respirator AG700
AG700
- Standard
- EN 136:1998, Klasse 2
- Connection
- Bayonet + RD40
- Protects up to
- 400× AGW