AGA2E2Combination filter, RD40

Combination filter A2E2P3 with RD40 thread

Single filter of gas class 2 for the central connection of the full-face mask AG700: A2 against organic gases and vapours with a boiling point above 65 °C, E2 against acid gases, plus P3 against particles.

Marking
A2E2P3
Standard
EN 14387:2021
Connection
RD40
Fits
AG700
PPE category
III, CE 2834
Packaging
20 pieces

Data sheet (PDF)Ask for advice

Warnings

  • Replace gas filters according to a change schedule, at the latest when odour, taste or irritation is noticed. Then leave the area immediately.
  • Do not use filters containing activated carbon for firefighting, near open flames or with molten metal splashes.
  • Filters do not supply oxygen: do not use where the oxygen content may be too low (below 19.5 % by volume according to the instructions for use), in tanks, pits, shafts and confined spaces, or if the substance and its concentration are not known.
  • Use only with the AirGuard Pro masks named in the documents.

The instructions for use of the product are authoritative.

AirGuard Pro Combination filter A2E2P3 AGA2E2, black

Class 2: up to 0.5 % by volume

Class 2 gas filters are permitted up to a gas concentration of 0.5 % by volume (5,000 ml/m³), five times as high as class 1. For lower concentrations and the half mask there is the AGA1E1 with bayonet.

With the full-face mask AG700 the filter is permitted up to 400 times the workplace exposure limit under DGUV Rule 112-190. It does not protect against ammonia (K) and inorganic gases (B); for these there is the AGABEK2P3.

For the full-face mask only

The RD40 thread only fits the full-face mask AG700. The side bayonet connections stay closed. Replace the filter according to a change schedule, at the latest at odour, taste or irritation; according to the instructions for use it can be used for a further shift after a passed blockage check.

The declaration of conformity and instructions for use are available on request.

Using correctly

  1. 01

    Open only at the place of use

    Take the filter out of its packaging immediately before use and check the expiry date on the filter.

  2. 02

    Screw in centrally

    Keep the side connections of the AG700 closed and screw the filter clockwise into the RD40 thread until tight.

  3. 03

    Check the face seal

    Place the palm of your hand over the exhalation valve and exhale slowly. If air escapes at the edge of the mask, reposition it and tighten the straps. Before every use.

  4. 04

    Replace in good time

    According to the change schedule, at the latest when odour, taste or irritation is noticed. Replace the filter too if breathing becomes harder.

When filters are replaced

Technical data

Technical data AGA2E2
Article numberAGA2E2
TypeCombination filter
Colourblack
StandardEN 14387:2021
MarkingA2E2P3
Gas filterType A and E, class 2 (up to 0.5 % by volume)
Particle filterP3
ConnectionRD40 thread, one filter
FitsAG700
PPE categoryIII under Regulation (EU) 2016/425
Notified bodyCCQS Certification Services Limited, 2834
EU type examinationCE-PC-240129-058-04-9A of 24 Oct 2024
Packaging20 pieces, each in a box

Downloads

Instructions for use and Declaration of conformity on request: Request documents

Frequently asked questions

What does A2E2P3 mean?

A2: organic gases and vapours with a boiling point above 65 °C, E2: acid gases, each class 2 up to 0.5 % by volume. P3: particle filter of the highest class.

Does the AGA2E2 fit the half mask?

No. It has an RD40 thread and only fits the full-face mask AG700. For the half mask there is the combination filter AGA1E1 (A1E1P3 R D) with bayonet.

When do I need class 2 instead of class 1?

When the gas concentration is above 0.1 % by volume. Class 2 is permitted up to 0.5 % by volume.